Bolted Joint Calculator

Preload, torque & strength · VDI 2230 method · v0.5

1Joint type

2Bolt
Head

3Clamped parts
Tapped part

4Friction & tightening
Tighten to
5Loads per bolt

Axial and transverse loads come from the bolt pattern (section 6): the most loaded bolt is checked.

Distances from the centre of the interface (axis of the symmetric deformation body), positive towards the edge U where the joint would open first.

6Bolt pattern

Start from: ·

Loads on the whole flange: Fz at (xF, yF), the others at the pattern centre (centroid C for custom positions). z is the bolt axis (pulling the joint apart is +); moments follow the right-hand rule.

7Aerospace check

Factors of safety and the fitting factor are programme requirements (e.g. NASA-STD-5001): the defaults are typical values. Loads in section 5 are limit loads per bolt.

Tightening torque MA
—

Joint cross-section

deformation coneengaged thread

Deformation cone of the clamped parts (VDI 2230 substitute body) and the bolt zones used for the resilience δS.

Joint diagram

boltclamped partsat FM,max

Force against elongation at the minimum preload after embedding, with the axial load FA split into the extra bolt load FSA and the relief of the parts FPA.

Design checks

VDI 2230-1 steps

Thread & stress area

Preload scatter from friction

Preload at the tightening torque across the friction range (shaded). The red line is where the bolt reaches its yield point during tightening.

How the tightening torque is used (at μmin)

Thread engagement & stripping

Calculation steps and formulas
Libraries: threads, property classes, materials, friction, tightening
Method, assumptions and references
  • The calculation follows VDI 2230 Part 1 (2015) for a single bolt; the optional cards add eccentric clamping and loading, prying, bolt patterns with rigid, beam or plate flanges and flexible bases, and the NASA-STD-5020 checks. Finite-element methods (VDI 2230 Part 2) are not covered.
  • Bolt resilience δS is the sum of the head, shank, free thread, engaged thread and nut / tapped thread zones (lSK = 0.5d hex, 0.4d socket head; lG = 0.5d; lM = 0.4d nut, 0.33d tapped thread).
  • Plate resilience δP uses the deformation cone / sleeve substitute body with the cone angle φ from VDI 2230 eq. (5.1/42, 5.1/43). Parts of different materials are combined with a length-weighted series modulus.
  • Embedding fZ from VDI 2230 table 5 per thread, per head/nut bearing and per inner interface; transverse loads use the shear column. Inserts add one thread interface.
  • Thread stripping uses the shear areas of the ISO basic profile (FED-STD-H28 / ISO 898 form) with τB = fτ·Rm, the nut dilation factor C1 (VDI 2230) and a combined thread bending and tolerance factor 0.9. Heli-Coil: STI tapped hole major Ø ≈ d + 1.3P. Solid inserts: outer thread entered by the user; the steel insert body is assumed with Rm = 800 MPa.
  • Fatigue: endurance limit of the thread σASV = 0.85(150/d + 45) (rolled before heat treatment) or σASG = (2 − FSm/F0.2)·σASV (rolled after), for N ≥ 2·10⁶ cycles.
  • Limiting surface pressures pG are from VDI 2230 table A9 where available; values marked ~ in the material library are typical estimates. Always check with the supplier's data for your exact material and condition.

References: VDI 2230 Blatt 1:2015 Systematic calculation of highly stressed bolted joints; ISO 898-1, ISO 3506-1, ISO 261, ISO 724, ISO 273, ISO 4017, ISO 4032, ISO 4762, ISO 7089/7093, ISO 16047 (torque/clamp force testing), DIN 8140 (wire thread inserts); FED-STD-H28/2B (thread shear areas); Bickford, Introduction to the Design and Behavior of Bolted Joints.

Results are design guidance and do not replace testing or a full VDI 2230 analysis for safety-critical joints.

Bolted Joint Calculator

Version 0.5 · by E. Tozlu

A free, browser-based tool for engineers, makers, designers and students to size and check bolted joints: preload, tightening torque, the joint diagram, the deformation cone of the clamped parts, embedding, temperature effects, fatigue, surface pressure under the head and thread stripping in nuts, tapped holes, Heli-Coil wire inserts and solid threaded inserts. All calculations run in your browser and every formula is shown with your numbers.

The method follows the public literature on bolted joints, mainly VDI 2230 Part 1, with friction data from VDI 2230 and ISO 16047 coating specifications. Not affiliated with or endorsed by VDI or any fastener manufacturer. Heli-Coil is a trademark of its owner and is used only to name the insert type.

Made by E. Tozlu. More engineering tools at tools.ehcrea.com and ehcrea.com.

Open source under the MIT License; the source code is on GitHub.

Finding it useful? The tool is free for everyone and I build it in my spare time. You can support its development on Patreon.

Support me on Patreon

Results are design guidance. Confirm critical joints by testing and with a full VDI 2230 analysis.

How to use the Bolted Joint Calculator

New here? Pick an example from Load application example… in the toolbar, then change one value at a time and watch the results.

Five steps

  1. Joint type: a through bolt with a nut, a bolt in a tapped hole, a bolt in a Heli-Coil (wire thread insert) or in a solid threaded insert.
  2. Bolt: thread size, property class, head type, plain shank and washers.
  3. Clamped parts: the stack of parts between head and nut (or tapped part), with material and thickness; the hole and the width of material around the bolt; for tapped joints the material and the thread engagement length.
  4. Friction & tightening: the surface and lubrication sets the friction range; the tightening method sets the preload scatter αA. Tighten to 90 % of the yield point (VDI default) or enter a torque.
  5. Loads per bolt: axial (static or cyclic), transverse, extra clamp load, temperature change.

Key terms

Preload FM
Tension in the bolt after tightening. It scatters between FM,min and FM,max = αA·FM,min because of friction and the tightening tool.
Stress area AS
Cross-section used for the bolt stress, with the mean of the pitch and minor diameters.
Load factor Φ
Share of the axial load that adds to the bolt force. The rest only reduces the clamp load. A stiff joint and an elastic bolt give a small Φ.
Deformation cone
The zone of the clamped parts that carries the clamp load, spreading from the head at the angle φ.
Embedding FZ
Preload lost when the surface roughness peaks flatten after assembly.
Residual clamp load FKR
Clamp force left in the interface under the maximum load: it must stay above what is needed for friction grip or sealing.
Thread stripping
The thread flanks shear off. Good design makes the bolt break first: a longer engagement or an insert in soft materials.

The Calculation steps section shows every formula with your numbers so you can follow or check the result by hand.

Galling

Stainless steel and titanium are protected by a thin oxide layer and harden quickly. Under thread pressure and sliding, the oxide is wiped off and the surfaces cold-weld: the torque jumps, the joint seizes before the preload is reached, and the bolt can twist off or the thread tear out. This is galling (thread seizure).

Galling is not a calculated limit: it depends on surface finish, speed, cleanliness and coating, so the tool gives warnings and notes rather than a pass/fail check. The dry titanium friction range is an estimate.

Bolt patterns

Tick Loads act on a bolt pattern in section 6 and enter the forces and moments on the whole flange. The axial load Fz can act off-centre at (xF, yF). The bolts form a circle, a rectangular grid, or custom positions: paste x, y in mm, one bolt per line, from any origin (a drawing datum, or two columns from a spreadsheet). For custom patterns the coordinates and xF, yF use your origin; the tool moves everything to the bolt-group centroid C, which is shown in the plan view. Start from copies the current circle or grid into the list so you can edit single bolts. By default the tool treats the flange as rigid (the classical bolt-group model):

Mixed bolt sizes, property classes, joint types and clamped parts (custom positions). Add a thread size, a property class, a joint type and/or a part stack after a bolt's coordinates, in any order: 80, 0, M6, 80, 0, 12.9, 80, 0, tapped or 80, 0, M6, A4-70, helicoil (joint types: nut, tapped, helicoil or hc, insert; part stacks: 80, 0, @boss). What a line leaves out comes from sections 1–3. A stiffer bolt takes a larger share of the load, so with mixed bolts:

The joint stiffness depends on the parts as well as the bolt, so a bolt twice the size does not take four times the load. Equal joint stiffness is assumed for bolts of the same size.

Flexible flange (centroid model). A rigid flange shares a load by lever arms alone. A real flange bends, so the bolts close to a local load take more and the distant ones less. Tick Flexible flange and choose the flange model: a beam along x (rectangular grids only) or a plate (any pattern). The beam is Euler–Bernoulli, width Ly, thickness t, E of the first clamped part, resting on one spring per bolt column:

Plate flange. The flange is a Kirchhoff plate (bending stiffness D = E·t³/(12(1 − ν²)), ν = 0.3) over its outline: Lx × Ly for a grid, the flange Ø for a circle, and for custom positions the bolt field plus the edge distance. It is meshed with about 32 rectangular ACM plate elements on the long side, with a grid line through every bolt, and solved with a banded Cholesky factorisation in the browser.

The flexible models assume a joint that stays closed at every bolt (the contact between flange and base outside the bolts is not modelled) and a plate that bends elastically. The mesh changes the bolt loads by about ±3 %. Opened joints, contact and membrane effects need FEA. Prying forces and the VDI 2230 eccentric case of a single bolt are separate options (sections 5 and 6).

Prying

When a web or an angle leg pulls on a flange, the flange bends, its outer edge presses on the support, and it levers an extra force Q onto the bolt: the bolt carries B = T + Q. Tick Flange prying in section 5 and enter, per bolt, the distance to the web face b, the distance to the flange edge a, the flange width per bolt w and the flange thickness t.

Plastic T-stub check (ultimate limit state). The elastic formula describes the joint in service; codes for steel structures check the flange and bolt at failure with plastic hinges. Choose EN 1993-1-8, AISC Manual Part 9 or both, and a design load factor γ (the service load T per bolt times γ is the design load). Both are evaluated per bolt, as half a T-stub (or one angle leg) with the flange width w:

The formula is elastic and assumes a flange that does not yield. Use the plastic T-stub check for the ultimate limit state. Reduce prying with a thicker flange, bolts closer to the web, or stiffeners.

Eccentric clamping and loading

Many joints are not symmetric: the bolt sits off the centre of the contact face (eccentric clamping, offset ssym), or the load acts beside the bolt (eccentric loading, offset a), for example on a bracket or a cover flange. The parts then bend as well as compress. Tick Eccentric clamping and loading in section 5 and enter the size of the contact face cT × bT and the offsets, measured from the centre of the contact face, positive towards the edge U where it would open first.

Opened joint. Above the opening limit FAab (where the closed-joint residual clamp load falls to FKA) the interface lifts at U and only a shrinking contact zone towards the far edge V carries the clamp load. The bolt force then rises faster than Φen*·FA and tends to the lever law FS = FA·ξA/ξB (ξ = distance of the load line and of the bolt from V). The tool models this with an elastic no-tension interface: a stiff flange on an elastic layer over cT × bT with the axial resilience δP, linear contact pressure and no tension, joined to the VDI line at FAab. A bending moment MB is taken to grow with the load, so in this branch it moves the load line by MB/FA,max. Once the joint opens:

The opened-joint branch is the tool's own engineering model, not the method of VDI 2230 Part 1 Annex D; check critical joints against the guideline or with FEA. The formulas follow VDI 2230 Part 1 (2015) in simplified form and should be checked against the guideline for critical joints. Do not combine with prying: both describe the same bending flange.

Aerospace check (NASA-STD-5020)

Spaceflight hardware for NASA follows NASA-STD-5020 (threaded fastening systems); ESA uses ECSS-E-HB-32-23A. Tick Also check to NASA-STD-5020 in section 6 to run it next to VDI 2230 on the same joint. The main differences:

This is a simplified implementation for design studies: the defaults are typical values, and your programme's revision of the standard, its factors of safety and its allowables (e.g. MMPDS) govern. The load factor nφ comes from the VDI 2230 stiffness model.

Locking elements

A joint comes loose in two ways: it loses preload (settling, creep, temperature), or the screw turns loose under transverse vibration (Junker test, DIN 65151 / ISO 16130). Enough preload is the first defence against both. Locking elements help with only one of them:

Lock washer dimensions, flat loads and thread-locker friction are typical catalogue values (marked ~ or noted as estimates): check your supplier's data.

Mounting circuit boards (PCBs)

Choose PCB FR-4 as a clamped part. A board behaves differently from a metal plate:

M3 screw with washer, 1.6 mm board on a brass standoff, oiled steel screw, torque wrench. Calculated live from the "PCB on a standoff" example:

TorquePreloadBoard pressureLeft after settling

Good practice:

The FR-4 values (Ez, expansion and the 100 MPa pressure limit) are estimates: no standard gives a limiting pressure for circuit boards. Use your laminate supplier's data where it matters.