How to use the Bolted Joint Calculator
New here? Pick an example from Load application example… in the toolbar, then change one value at a time and watch the results.
Five steps
Joint type : a through bolt with a nut, a bolt in a tapped hole, a bolt in a Heli-Coil (wire thread insert) or in a solid threaded insert.
Bolt : thread size, property class, head type, plain shank and washers.
Clamped parts : the stack of parts between head and nut (or tapped part), with material and thickness; the hole and the width of material around the bolt; for tapped joints the material and the thread engagement length.
Friction & tightening : the surface and lubrication sets the friction range; the tightening method sets the preload scatter αA . Tighten to 90 % of the yield point (VDI default) or enter a torque.
Loads per bolt: axial (static or cyclic), transverse, extra clamp load, temperature change.
Key terms
Preload FM Tension in the bolt after tightening. It scatters between FM,min and FM,max = αA ·FM,min because of friction and the tightening tool.
Stress area AS Cross-section used for the bolt stress, with the mean of the pitch and minor diameters.
Load factor Φ Share of the axial load that adds to the bolt force. The rest only reduces the clamp load. A stiff joint and an elastic bolt give a small Φ.
Deformation cone The zone of the clamped parts that carries the clamp load, spreading from the head at the angle φ.
Embedding FZ Preload lost when the surface roughness peaks flatten after assembly.
Residual clamp load FKR Clamp force left in the interface under the maximum load: it must stay above what is needed for friction grip or sealing.
Thread stripping The thread flanks shear off. Good design makes the bolt break first: a longer engagement or an insert in soft materials.
The Calculation steps section shows every formula with your numbers so you can follow or check the result by hand.
Galling
Stainless steel and titanium are protected by a thin oxide layer and harden quickly. Under thread pressure and sliding, the oxide is wiped off and the surfaces cold-weld: the torque jumps, the joint seizes before the preload is reached, and the bolt can twist off or the thread tear out. This is galling (thread seizure).
Highest risk : a stainless or titanium bolt in a mating thread of a like material (a stainless nut, a Heli-Coil, which is stainless wire, or a tapped hole in stainless or titanium), with dry threads. The tool warns for this pair, for a stainless or titanium bolt with dry threads in general, and when a friction option for steel bolts is chosen for a stainless or titanium bolt (those values are wrong for it too).
Notes only : a wet thread-locker (it lubricates only partly) and custom friction values with a like-material pair. With an anti-seize paste (stainless or titanium option, or MoS2 ) there is no message.
Prevention : anti-seize paste on the thread and under the head; coated or silver-plated bolts; materials of different hardness (e.g. a Nitronic 60 or coated steel nut, dry-film-coated Heli-Coils); coarse threads rather than fine; slow, steady tightening (no impact or fast power drivers, which heat the thread); clean threads; do not reuse galled parts.
Galling is not a calculated limit: it depends on surface finish, speed, cleanliness and coating, so the tool gives warnings and notes rather than a pass/fail check. The dry titanium friction range is an estimate.
Bolt patterns
Tick Loads act on a bolt pattern in section 6 and enter the forces and moments on the whole flange. The axial load Fz can act off-centre at (xF , yF ). The bolts form a circle, a rectangular grid, or custom positions : paste x, y in mm, one bolt per line, from any origin (a drawing datum, or two columns from a spreadsheet). For custom patterns the coordinates and xF , yF use your origin; the tool moves everything to the bolt-group centroid C, which is shown in the plan view. Start from copies the current circle or grid into the list so you can edit single bolts. By default the tool treats the flange as rigid (the classical bolt-group model):
Shear Fx , Fy is shared equally; torsion Mz adds a shear Mz ·ri /Σr² at right angles to each bolt radius.
Tension Fz is shared equally; bending adds M·yi /Σy² about the bolt-group centroid (centroid model , valid while the preloaded joint stays closed; for unsymmetric patterns with Σxy ≠ 0 the tool solves Σx²·b + Σxy·c = −My , Σxy·b + Σy²·c = Mx and uses FA,i = Fz /n + b·xi + c·yi ; bolts on one line cannot carry the moment about that line, which is flagged) or M·hi /Σh² about the flange edge (heel model , for a joint that has opened or for ultimate loads; for custom patterns the edge lies the given distance beyond the outermost bolt).
The bolt with the highest tension and the highest shear are combined into one design bolt (conservative if they are different bolts), which runs through all the checks.
Mixed bolt sizes, property classes, joint types and clamped parts (custom positions). Add a thread size, a property class, a joint type and/or a part stack after a bolt's coordinates, in any order: 80, 0, M6, 80, 0, 12.9, 80, 0, tapped or 80, 0, M6, A4-70, helicoil (joint types: nut, tapped, helicoil or hc, insert; part stacks: 80, 0, @boss). What a line leaves out comes from sections 1–3. A stiffer bolt takes a larger share of the load, so with mixed bolts:
Tension is shared in proportion to each bolt's joint stiffness k = 1/δS + 1/δP (VDI 2230 resiliences of that size in the same joint), about the stiffness-weighted centroid G: FA,i = ki ·(Fz /Σk + b·xi + c·yi ). With the heel model: ki ·Fz /Σk + M·ki ·hi /Σk·h².
Shear is shared in proportion to the stress area AS about the area-weighted centroid (the usual elastic method for bolt groups of different diameters).
Every bolt type (size, class, joint type and part stack) is checked with the full VDI 2230 method under its own highest tension and shear, with its own parts and the same friction and tightening method. A failing type is reported at the top. The detailed results are for the bolt from section 1; Check in detail opens another type (the other lines get their size, class, joint type and part stack written out, so the pattern does not change; the old parts of section 2 are kept as a stack named base).
Property class changes the strength and the preload, and the stiffness only through E: steel classes share load equally, stainless (E ≈ 193 GPa) and titanium (E ≈ 114 GPa) bolts are softer and take a little less. A typical use is upgrading only the most loaded bolts (e.g. one row to 12.9). Bolts of the same size but different class look alike, so mark them and control them in assembly.
Joint type uses the same stack of parts. A screw joint in a through-bolted pattern threads into the last clamped part: that part becomes the threaded part (its material; thread depth = its thickness, at most 1.5·d for a tapped hole, the coil length for a Heli-Coil). A through-bolt in a screw-joint pattern also clamps the threaded part, taken as thick as the engagement length (or as thick as it was, after switching with Check in detail ). The screw joint has a much shorter clamp length, so it is stiffer and takes a larger share of the load, and it loses more preload to embedding: check it on its own (the table does).
Clamped parts : where some bolts clamp other parts (a thicker boss or rib, a spacer, a bracket of another material), define a part stack, one per line, as boss: S235 10, S235 45 (material and thickness from under the head; a thickness alone keeps the material of that position in section 2) and write @boss on those bolt lines. Each stack has its own clamp length, joint stiffness and bolt length. A longer or softer stack makes the bolt softer, so it takes less of the tension and the stiffer bolts take more; and the longer bolt loses less preload to embedding. The stack is written for the joint type of section 1: for a tapped line the last part of the stack becomes the threaded part.
Mixing stainless or titanium with steel bolts brings the galling and friction warnings of that class into the check of its type (e.g. a stainless bolt with a friction option for steel).
Inputs that scale with the bolt (engagement length, custom hole) are scaled by d for the other sizes. A given torque applies to the section-1 size only; the other sizes are tightened to ν.
The joint stiffness depends on the parts as well as the bolt, so a bolt twice the size does not take four times the load. Equal joint stiffness is assumed for bolts of the same size.
Flexible flange (centroid model). A rigid flange shares a load by lever arms alone. A real flange bends, so the bolts close to a local load take more and the distant ones less. Tick Flexible flange and choose the flange model: a beam along x (rectangular grids only) or a plate (any pattern). The beam is Euler–Bernoulli, width Ly , thickness t, E of the first clamped part, resting on one spring per bolt column:
Spring stiffness per bolt k = 1/δS + 1/δP , the stiffness of the closed, preloaded joint against an external load (bolt stretching and parts unloading in parallel). It comes from the same VDI 2230 resiliences as the single-bolt check.
Fz at xF and My load the beam. It is solved with beam finite elements (exact for point loads), giving each column load R = kcol ·w, the deflection line and the largest flange bending moment. Along y the flange stays rigid: Mx (including Fz ·yF ) is shared by yi /Σy².
The result is compared with the rigid model bolt by bolt, and the flange bending stress Mmax /(Ly ·t²/6) is checked against Rp . A very thick flange gives the rigid result; a thin one puts most of the load on the nearest bolt.
Plate flange . The flange is a Kirchhoff plate (bending stiffness D = E·t³/(12(1 − ν²)), ν = 0.3) over its outline: Lx × Ly for a grid, the flange Ø for a circle, and for custom positions the bolt field plus the edge distance. It is meshed with about 32 rectangular ACM plate elements on the long side, with a grid line through every bolt, and solved with a banded Cholesky factorisation in the browser.
Each bolt is a point spring ki = 1/δS + 1/δP (per bolt type for mixed bolts). Its load is FA,i = ki ·(wflange − wbase ) at the bolt.
The loads enter through a stiff hub or web (3× the flange thickness), centred at (xF , yF ): a disc for circular flanges, a rectangle otherwise. Enter its real size; blank estimates it from the bolt spacing. Fz , Mx and My are spread over its nodes with their resultant exactly at (xF , yF ), so Σ FA and the moments match the rigid model.
Flexible base : instead of a rigid foundation, a second plate of the same outline (thickness and material of the last clamped part or the tapped part, or your own) lies under the joint. It is either simply supported along its edge (a frame or box around the flange) or bedded on a Winkler foundation with modulus ks (N/mm³). A very thick or very stiffly bedded base gives the rigid-base result.
The von Mises bending stress σv = √(σx ² + σy ² − σx σy + 3τ²), σ = 6m/t², is read at the element centres, t/2 away from the hub or web and from the bolt heads, where a plate model with point supports is singular. It is checked against Rp for the flange and for the base. It is a nominal stress: welds and fillets at the web toe need their own check.
The flexible models assume a joint that stays closed at every bolt (the contact between flange and base outside the bolts is not modelled) and a plate that bends elastically. The mesh changes the bolt loads by about ±3 %. Opened joints, contact and membrane effects need FEA. Prying forces and the VDI 2230 eccentric case of a single bolt are separate options (sections 5 and 6).
Prying
When a web or an angle leg pulls on a flange, the flange bends, its outer edge presses on the support, and it levers an extra force Q onto the bolt: the bolt carries B = T + Q. Tick Flange prying in section 5 and enter, per bolt, the distance to the web face b, the distance to the flange edge a, the flange width per bolt w and the flange thickness t.
Prying ratio (Douty & McGuire elastic formula, in Kulak, Fisher & Struik): Q/T = (½ − X/30) / ((a/b)·(a/3b + 1) + X/6) with X = w·t⁴/(a·b²·Ab ). A thick flange (X above 15) does not pry; a is limited to 1.25·b.
The prying force is added to the axial load of the bolt (as in ECSS-E-HB-32-23A), so all checks, including fatigue and NASA-STD-5020, see it. With a bolt pattern it acts on the most loaded bolt.
Flange bending is checked at the web face (|T·b − Q·a|) and at the bolt line (Q·a, net width w − dh ) against the yield strength of the first clamped part.
Plastic T-stub check (ultimate limit state). The elastic formula describes the joint in service; codes for steel structures check the flange and bolt at failure with plastic hinges. Choose EN 1993-1-8 , AISC Manual Part 9 or both, and a design load factor γ (the service load T per bolt times γ is the design load). Both are evaluated per bolt, as half a T-stub (or one angle leg) with the flange width w:
EN 1993-1-8 (Table 6.2, method 1, leff = w): m = b − 0.8·r (r = root radius; for a welded web √2·aw ), n = min(a, 1.25·m), Mpl,Rd = 0.25·leff ·t²·fy /γM0 , Ft,Rd = 0.9·fub ·As /γM2 . Per bolt: mode 1 (flange yields) 2·Mpl /m, mode 2 (bolt fails with flange yielding) (Mpl + n·Ft,Rd )/(m + n), mode 3 (bolt fails) Ft,Rd . If the bolt is long, Lb = lK + (head + nut)/2 > Lb * = 8.8·m³·As /(leff ·t³), no prying develops and modes 1–2 give Mpl /m. leff = w is the simple case of a bolt row away from ends and stiffeners: end bolts and bolts near a stiffener have the circular and corner patterns of Table 6.4–6.6.
AISC Manual Part 9 (LRFD, in SI): B = φ·Fnt ·Ab with Fnt = 0.75·Fu of the bolt and φ = 0.75; b' = b − d/2, a' = min(a, 1.25·b) + d/2, ρ = b'/a', δ = 1 − d'/p (p = w). The flange thickness that needs no prying is tc = √(4·B·b'/(φ·p·Fu )) with φ = 0.90; the available tension is B·(t/tc )²·(1 + δ·α') with α' = ((tc /t)² − 1)/(δ·(1 + ρ)) ≤ 1, and the card also gives the required thickness treq and the prying force q at the design load.
The plastic checks do not change the service bolt load: VDI 2230 still uses T + Q from the elastic formula. They need a ductile flange with a yield strength (not cast iron).
The formula is elastic and assumes a flange that does not yield. Use the plastic T-stub check for the ultimate limit state. Reduce prying with a thicker flange, bolts closer to the web, or stiffeners.
Eccentric clamping and loading
Many joints are not symmetric: the bolt sits off the centre of the contact face (eccentric clamping, offset ssym ), or the load acts beside the bolt (eccentric loading, offset a), for example on a bracket or a cover flange. The parts then bend as well as compress. Tick Eccentric clamping and loading in section 5 and enter the size of the contact face cT × bT and the offsets, measured from the centre of the contact face, positive towards the edge U where it would open first.
Load factor: the bending resilience of the parts βP = lK /(EP ·ĪBers ) gives δP * = δP + ssym ²·βP and δP ** = δP + ssym ·a·βP , and Φen * = n·δP **/(δS + δP *). A load further out than the bolt (a > ssym ) raises the load factor, often several times.
One-sided opening: the joint lifts at U unless the residual clamp load is at least FKA = (FA ·(a − ssym )·u + MB ·u)/(IBT /AD + ssym ·u). FKA enters the required clamp load and has its own check in R10.
Bolt bending: the bending of the parts also bends the bolt. The alternating stress in R9 is multiplied by 1 + (a/Φen * − ssym )·(lK /lers )·(ES /EP )·π·dS ³/(8·ĪBers ).
ĪBers , the bending inertia of the clamped parts, is estimated from a cylinder with the same axial resilience as δP , limited to IBT of the contact face. This tends to be low, so bolt bending comes out on the safe side; enter a better value (FEA, or the deformation-body formulas of VDI 2230 Part 1) when you have one.
Opened joint. Above the opening limit FAab (where the closed-joint residual clamp load falls to FKA ) the interface lifts at U and only a shrinking contact zone towards the far edge V carries the clamp load. The bolt force then rises faster than Φen *·FA and tends to the lever law FS = FA ·ξA /ξB (ξ = distance of the load line and of the bolt from V). The tool models this with an elastic no-tension interface: a stiff flange on an elastic layer over cT × bT with the axial resilience δP , linear contact pressure and no tension, joined to the VDI line at FAab . A bending moment MB is taken to grow with the load, so in this branch it moves the load line by MB /FA,max . Once the joint opens:
FS,max (R8) and the stress amplitude (R9) use the opened bolt force, and the bolt bending adds the tilt of the flange to the bending of the parts. The card shows the bolt force against the load: closed line, opened curve and lever law.
FKR,min becomes the contact force left at the tipping side, FS − FA , which is what resists slip. The joint does not lift off as a whole while the load acts further out than the bolt.
The opening check fails unless Opening allowed is ticked; then FKA leaves the required clamp load and the check is a warning. Allow it only for rare or static overloads: under alternating loads the amplitude grows quickly and the gap lets fretting and corrosion in.
The opened-joint branch is the tool's own engineering model, not the method of VDI 2230 Part 1 Annex D; check critical joints against the guideline or with FEA. The formulas follow VDI 2230 Part 1 (2015) in simplified form and should be checked against the guideline for critical joints. Do not combine with prying: both describe the same bending flange.
Aerospace check (NASA-STD-5020)
Spaceflight hardware for NASA follows NASA-STD-5020 (threaded fastening systems); ESA uses ECSS-E-HB-32-23A. Tick Also check to NASA-STD-5020 in section 6 to run it next to VDI 2230 on the same joint. The main differences:
Preload range from the torque range: Ppi = (1 ± Γ)·T / (K·d), with the nut factor K at the mean friction, the drawing torque tolerance, and the preload uncertainty Γ (by default ±25 % lubricated, ±35 % dry; smaller from torque–tension tests or measured preload). The running torque of a locking feature is subtracted unless the torque is specified above it.
Service preload: minus relaxation (the larger of a percentage and the VDI 2230 embedding) and temperature effects.
Factored limit loads with factors of safety and a fitting factor, and margins of safety MS = allowable / factored load − 1, which must be ≥ 0: separation and slip with the minimum preload, yield with the maximum preload, ultimate tension without preload (ductile fastener), thread shear-out, bolt shear and the tension–shear interaction.
Locking feature required on safety-critical fasteners.
This is a simplified implementation for design studies: the defaults are typical values, and your programme's revision of the standard, its factors of safety and its allowables (e.g. MMPDS) govern. The load factor nφ comes from the VDI 2230 stiffness model.
Locking elements
A joint comes loose in two ways: it loses preload (settling, creep, temperature), or the screw turns loose under transverse vibration (Junker test, DIN 65151 / ISO 16130). Enough preload is the first defence against both. Locking elements help with only one of them:
Split lock washer (DIN 127, withdrawn in 2003): pressed flat far below the preload, then only adds contact faces that settle. VDI 2230 Part 1 calls it ineffective in preloaded joints. The calculator adds its layer and the extra embedding, and warns.
Conical spring washer (DIN 6796) or disc springs: a spring in series with the bolt. Once settling lowers the force below its flat load it springs back and keeps most of the preload. Calculated with a linearised spring rate from the flat load and the spring travel.
Wedge-locking washer pair (tested to DIN 25201): stops the screw turning loose, but does not stop settling. Calculated as a washer pair with one more contact face.
Thread-locking adhesive (anaerobic, ISO 10964; MIL-S-22473 / ASTM D5363 in defence): stops the screw turning loose and seals the thread. Applied wet, it changes the friction during tightening, so choose a thread-locker friction entry. It adds no preload and does not stop settling.
Lock washer dimensions, flat loads and thread-locker friction are typical catalogue values (marked ~ or noted as estimates): check your supplier's data.
Mounting circuit boards (PCBs)
Choose PCB FR-4 as a clamped part. A board behaves differently from a metal plate:
Soft through its thickness. FR-4 has Ez ≈ 10 GPa, about 1/20 of steel. Under preload the board compresses 15 µm, more than the screw stretches (8 µm) , so a large share of any pull-off load (ΦK ≈ 0.6 for an M3 through 1.6 mm) reaches the screw.
That softness helps against settling. The embedding of head, washer and thread (about 9 µm) costs 58 % of the minimum preload, against all of it in a 1.6 mm steel plate . Thicker boards keep more preload.
The board limits the torque, not the screw. At 0.6 N·m, the highest torque that keeps the board pressure within 2/3 of its limit, an M3 8.8 screw uses only about 45 % of its yield strength.
Creep is the main long-term loss , especially above about 80 °C and near the glass transition Tg . The calculator warns about it but does not compute it.
Temperature: FR-4 expands about 60 ppm/K through its thickness (about 250 ppm/K above Tg ), about 5 times as much as a steel screw. Heating raises the screw force and the board pressure; cooling lowers the clamp.
M3 screw with washer, 1.6 mm board on a brass standoff, oiled steel screw, torque wrench. Calculated live from the "PCB on a standoff" example:
Torque Preload Board pressure Left after settling
Good practice:
Clamp on a bare copper or ENIG pad (a ring free of solder mask) a little larger than the washer.
Always use a washer, or a screw with a built-in washer or flange. Without one the head presses about 115 MPa into the board at 0.6 N·m (limit 100 MPa).
Use about 0.5–0.6 N·m for M3 with a controlled screwdriver. The lower end keeps at least 25 % of the preload after settling, the upper end keeps the board pressure within 2/3 of its limit. Against vibration use thread-locking compound or a locking feature rather than more torque.
Never tap threads into the board: use a nut, a standoff, or a press-fit or SMD nut.
Keep ceramic capacitors (MLCCs), BGAs and other strain-sensitive parts a few millimetres away from mounting holes.
Load: PCB on a standoff Load: PCB in a housing
The FR-4 values (Ez , expansion and the 100 MPa pressure limit) are estimates: no standard gives a limiting pressure for circuit boards. Use your laminate supplier's data where it matters.